150L Vertical Steam Sterilizer Autoclave CE Stainless Steel
Product Details:
Place of Origin: | China |
Brand Name: | HAIYING |
Certification: | CE certificate |
Model Number: | XFH-150CA |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiable |
Packaging Details: | Wooden case |
Delivery Time: | 5-8 work days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 10000 Set/Sets per day |
Detail Information |
|||
Model Number: Model Number: | XFH-150CA | Volume: | 150 L |
---|---|---|---|
Net Weight: | 130KG | Instrument Classification: | Class Ii |
Package: | 660*660*1220MM | Structure: | Stainless Steel |
Sterilization Chamber Size: | φ500*760MM | Power: | 6.0KW |
Highlight: | 150L vertical steam sterilizer autoclave,150L autoclave steam sterilizer,760MM vertical steam sterilizer autoclave |
Product Description
Stainless Steel Heating Tube Smooth Inside Vertical Autoclave Sterilizer
Vertical Autoclave Sterilizer Advantage:
◆ Fully stainless high-alloy steel structure
◆ Pressure and water level control
◆ The drying system is optional, which can be equipped according to the customers request
Model
|
Material
|
Volume
|
Power Supply
|
Output power
|
Dimension of sterilizing chamber
|
Net weight
|
Package Size
|
XFH-150CA
|
All stainless steel
|
150L
|
380V
|
6.0kW
|
φ500*760MM
|
130Kg
|
660*660*1220MM
|
Vertical autoclave sterilizer standard operating procedures
1. Vertical autoclave sterilizer the normal working conditions:.
A) environmental temperature + 5 ℃ ~ + 40 ℃
B) the relative humidity ≤ 80% RH
C) atmospheric pressure is 70 kPa to 106 kPa
D) work power to AC220V + 22 v, 50 Hz + 1 Hz
2. Vertical autoclave sterilizer method of use
2.1 water: add distilled water to the container, and to ensure that the water at least 3-5 cm higher than the electric heat pipe.
Note: due to will go to a certain amount of water consumption in the process of sterilization, so every time when using foot water should be in accordance with the above requirement, suggest using distilled water.
2.2 Stacked: items will be disinfected after wound into the sterilization in barrel, in order to avoid items plug valve was laid, should leave some space between and package, and steam osmosis, ensure the quality of sterilization.
Items within the stacking height should not exceed disinfection disinfection Jane height.
3.3 sealing: disinfection of tanks into the container, then put the container hose inserted sterilization barrels of semicircle groove. willContainer lid and container for the ears of the groove, and wrench will 6 to the wing bolt by to tighten, make the lid and container closed.
3.4 Vertical autoclave sterilizer heating operating procedures:
A) insert the plug into the power socket, small will bleed valve handle to facilitate the discharge of the cold air.
B) open preheating switch, preheat indicator, to have a nasty through purge valve steam purge valve should be under the small handle, as the heat continues, pressure gauge pointer began to rise and the steam pressure sterilizer.
C) the pressure control knob to adjust the sterilizing position (maximum pressure of
0. 142 Mpa)
D) will be the timer knob clockwise spiral refers to more than forecast the location of the heat preservation time about 10 minutes, then swing to forecast the location of the heat preservation time.
E) closed preheating switch, sterilizer into the constant temperature constant pressureState, during the heating indicator, destroy the alternate display (as a sterilizer for automatic constant temperature constant pressure), when the desired sterilization time, heating power supply will be automatically closed, lights out, and make a sound prompt, closing time switch, sterilization end.
Vertical Autoclave Sterilizer Note:
1) water overheat protection, such as container ignore aquatic or appear in the process of sterilization and water deficiency phenomenon, the sterilizationMachine will be automatic overheat protection, heating sterilizer will automatically cut off the power supply at this time and make a sound tip: after waiting for container with water, cooling, are plugged in and set up the sterilization temperature and time.
2) over current protection: when current overload, power fuse will automatically cut off the power, the fuse capacity of OA.
3) safety valve: when pressure exceeds 0165 Ma, automatic pressure, exhaust.

Want to Know more details about this product