16800 Rpm Automatic Rotor Serum Separation Centrifuge 3H16RI

16800 Rpm Automatic Rotor Serum Separation Centrifuge 3H16RI

Product Details:

Place of Origin: CHINA
Brand Name: HAIYING
Certification: CE
Model Number: 3H16RI

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Price: discuss personally
Packaging Details: wooden case
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Get Best Price Contact Now

Detail Information

Type: 3H16RI Max RCF: 19470×g
Max Speed: 16800r/min Timer Range: 1min-99h59min,with Continuous Run Function
Temp Control Range: -20℃~40℃ Power Supply: AV220V 50Hz
Standard Rotor: 12×1.5/2.0mL Max Capacity: 4×100mL
Highlight:

HAIYING Serum Separation Centrifuge

,

16800 Rpm large capacity refrigerated centrifuge

,

16800 Rpm Serum Separation Centrifuge

Product Description

Automatic Rotor Recognition Overspeed Door Cover Self-Locking Serum Separation High Speed Refrigerated Centrifuge
High Speed Refrigerated Centrifuge Features:
•  Easy programming to achieve high accuracy of speed control
•  Easy operation with intuitive menu and easy-to-read display
•  Rotor speed can be set and displayed by RPM or G-force
•  Maintenance-free brushless DC motors
•  Quick spin function with press and hold pulse key
•  Lid with electric lock and automatic release function saves processing time and prevents samples overheating
•  Automatic self-diagnosis on startup showing accumulative running time and last running parameters
•  Microcomputer control, DC brushless motor drive, stable operation, low noise and high speed precision.

 

Max RCF
19470×g
Max Speed
16800r/min
Max Capacity
4×100mL
Standard rotor
12×1.5/2.0mL
Temp control range
-20℃~40℃
Noise level
≤60dB(A)
Power supply
AC220V 50Hz

 

3H16RI high speed refrigerated centrifuge using the matters needing attention:
1. when using a variety of high speed refrigerated centrifuge, it must first obtain the precision to balance the centrifugal tube and balance on its contents, the difference between the balance weight must not exceed the range of the centrifuge instruction on regulations, each centrifuge turned to have their own allow difference, turn a pipe must not be loaded in the singular, when turned only partially loaded, pipe must be symmetrically placed in turn to each other, so that the load is evenly distributed around the turn.
2.  high speed refrigerated centrifuge load the solution, according to a variety of centrifuge concrete operation instructions, according to the stay of the nature and volume of centrifugal liquid to choose suitable centrifuge tube, some centrifugal tube without cover, liquid can not put too much, which prevent the centrifugal, turn imbalance, rust or corrode, and preparation of ultracentrifuge centrifuge tube, is often required must be filled with liquid, so as to avoid the centrifugal sag deformation at the top of the plastic centrifuge tube. , must check carefully after each use and head, timely clean, dry, turn is should focus on the protection of parts in the centrifuge, be careful when you move, not collision, avoid the scars, turn a long time need not when, to be coated with a layer of polishing wax protection, it is forbidden to use significant centrifugal pipe deformation, damage and aging.
3. If you want to in the below room temperature under the temperature of the centrifugal. Head should be placed in the refrigerator before use or in the turn of the centrifuge indoor precooling.
4. Shall not be arbitrarily in the process of centrifugal leave, should observe whether the instrument on the centrifuge to work properly, if there is any abnormal sound is necessary to stop the machine immediately to check and timely troubleshooting.

 