304SS Biological Safety Cabinet Sterile BSC Biosafety Cabinet
Product Details:
Place of Origin: | china |
Brand Name: | HAIYING-Biosafety cabinet |
Certification: | CE ISO |
Model Number: | BHC-1000A2 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 |
---|---|
Price: | negotiable |
Packaging Details: | The wooden case |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Detail Information |
|||
Features: | High Efficiency Filtration Sterile | Overall Size: | 1200×750×1950mm |
---|---|---|---|
Purification Area Size: | 1000×650×580mm | Filter Size: | 995×545×50mm |
Air Tightness: | 99.99≤E≤99.999 | Illumination: | ≥700LX |
Weight: | 160kg | Use: | Dust-Free Science Teaching And Research |
Highlight: | 700LX BSC Biosafety Cabinet,304SS biological safety cabinet,304SS BSC Biosafety Cabinet |
Product Description
BSC Biosafety Cabinet Features:
◆ Reliable quality biosafety cabinet
◆ Vertical air supply, intelligent control, variable air volume, stainless steel table
◆ A special filter is set up in the exhaust area to control the discharge of pollution.
◆ ir curtain isolation design prevents cross contamination between inside and outside.(Negative pressure)
◆ Equipped with a dedicated waterproof socket to provide great convenience for the operator.
◆ Using LED LCD panel control.
◆ The experimental area is made of high-quality 304 stainless steel, and the working area is equipped with a 2KW spare socket to provide convenience for the operator.
model | BHC-1000A2 |
purification area size | 1000×650×580MM |
purification efficiency | The 100 stage(America federal standard 209E) |
power | 0.8KW |
power supply | 220V 50HZ |
BSC Biosafety Cabinet Precautions:
1. In order to avoid cross-contamination between items, the items needed during the whole work process should be lined up and placed in the safety cabinet before the work starts, so that no items need to be taken out through the air flow compartment before the work is completed Put it in, pay special attention: no items can be placed on the front and rear return grilles to prevent the return grills from being blocked and affecting the air circulation.
2. Before starting work and after finishing work, it is necessary to maintain the air circulation for a period of time to complete the self-cleaning process of the safety cabinet. The cabinet should be cleaned and disinfected at the end of each test.
3. During the operation, try to reduce the number of arms in and out as much as possible, and the arms should be slow when entering and exiting the safety cabinet to avoid affecting the normal airflow balance.
4. The movement of items in the cabinet should follow the principle of moving from low pollution to high pollution, and the experiment operation in the cabinet should be carried out in the direction from the clean area to the contaminated area. Before operation, a towel soaked with disinfectant can be used as a bottom to absorb any droplets that may spill.
5. Try to avoid placing centrifuges, oscillators and other instruments in a safety cabinet to prevent the particulate matter on the filter membrane from shaking off when the instrument shakes, resulting in a decrease in the cleanliness of the cabinet; at the same time, the airflow of the heat dissipation vents of these instruments may affect the cabinet The airflow balance.
6. Do not use open flames in the safety cabinet to prevent the high temperature and fine particles generated during the combustion process from being brought into the filter membrane and damage the filter membrane.