• 8L Vertical Autoclave Sterilizer Anti Scald Protective Cover
  • 8L Vertical Autoclave Sterilizer Anti Scald Protective Cover
  • 8L Vertical Autoclave Sterilizer Anti Scald Protective Cover
  • 8L Vertical Autoclave Sterilizer Anti Scald Protective Cover
8L Vertical Autoclave Sterilizer Anti Scald Protective Cover

8L Vertical Autoclave Sterilizer Anti Scald Protective Cover

Product Details:

Place of Origin: China
Brand Name: HAIYING
Certification: CE certificate
Model Number: XFS-260/XFS-280A/XFS-280A+/XFS-280B/XFS-280MB/XFS-280CB/XFS-280B+/XFS-280MB+/XFS-280CB+

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Wooden case
Delivery Time: 5-8 work days
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 10000 Set/Sets per day
Get Best Price Contact Now

Detail Information

Name: Vertical Autoclave Sterilizer Particular: Microcomputer Motherboard Control
Tybe: Pressure Steam Sterilization Equipments Model: XFS-260/XFS-280A/XFS-280A+/XFS-280B/XFS-280MB/XFS-280CB/XFS-280B+/XFS-280MB+/XFS-280CB+
Sterilization Volume: 8L/18L/24L Feature: Eletric Heating
Temperature Range: 105~129℃ Power: 2.0KW
High Light:

8L Vertical Autoclave Sterilizer

,

8L high pressure steam sterilizer

,

120MM Vertical Autoclave Sterilizer

Product Description

Microcomputer Motherboard Control Anti-Scald Protective Cover Vertical Autoclave Sterilizer

Vertical Autoclave Sterilizer Advantage:

 

1.) High quality SUS304 stainless steel material

2.) Electric heating system

3.) Silicone seal

4.) Dual Scale indicate pressure gauge

5.) Safety valve and release valve

6.) High pressure faucet drainage

7.) Easy operation, safe and reliable

 

Chamber volume 240*120MM/280*235MM/280*340MM
Product name:
Pressure Steam Sterilization Equipments
power supply

220V

Instrument classification Class II
Power 1.0KW/2.0KW
Overall dimension 310*310*250MM/410*410*550MM/425+425*660MM
G.W/N.W 6.5KG/14.5KG/19KG/22.5KG

 


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Microcomputer Motherboard Control Anti-Scald Protective Cover Vertical Autoclave Sterilizer Matters needing attention:

 

◆ Different types of sterilization items is best not to at the same time, such as dressing and solution, rubber and equipment, etc. So as not to attend, can't get good sterilization effect.

◆ Must check before each heating water level, look to whether have enough storage. If discover water shortage alarm indicator and buzzer alarm, must immediately check the water level, with good water, close the power supply, make the heating work back to normal, water alarm light is put out, stop the buzzer alarm.

◆ Pay special attention to whether the water level of the conductive column in the table in the center of the gauge glass, if skewed will cause conducting column in the gauge glass cannot produce effect normally, even when the water level is low, can not be immediately cut off power supply. At the same time to have furring often view the conductive column tip.Because of scale will increase the resistance shall be immediately removed so as not to cause accidents.

◆ grounding equipment should be exact, to ensure safety.

◆ With the top of the relief valve installed on the device. Relief valve opening pressure of the factory has adjusted the, users don't move, so as to avoid accidents due to improper adjustment. Relief valve handle lifting 1-2 times a week, to ensure its sensitivity, and regular verification in accordance with provisions. Starts up, avoid by all means is in direct contact with the hand handle, application of screw Л or ѣ pull handle, in order to avoid scald the body of steam.

In the process of running, if put steam safety valve, which adjusts the setpoint of pressure controller, please. Method is: open the meter box, set aside the upper left of the rubber plug, pressure controller with screwdriver adjustment screw, make the red pointer to downward slightly positive pressure controller.

◆ When steam into the sterilization room, should slowly open front condensation control valves, trap make continuous discharge chamber air trap and condensed water, to ensure the sterilization effect.

◆ Sterilization chamber is made of stainless steel, water containing chlorine ion in the high temperature and high humidity environment is easy to cause stress corrosion. So after work to dry cleaning sterilizer sterilization room is very important.

 

 

8L Vertical Autoclave Sterilizer Anti Scald Protective Cover 0

Want to Know more details about this product
I am interested in 8L Vertical Autoclave Sterilizer Anti Scald Protective Cover could you send me more details such as type, size, quantity, material, etc.
Thanks!