CE 115L Automatic Autoclave Sterilizer Display Screen
Product Details:
Place of Origin: | China |
Brand Name: | HAIYING |
Certification: | CE certificate |
Model Number: | CT115A |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Negotiable |
Packaging Details: | Wooden case |
Delivery Time: | 5-8 work days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 10000 Set/Sets per day |
Detail Information |
|||
Tybe: | Automatic Autoclave Sterilizer | Model: | CT115 Standard Sterilizer |
---|---|---|---|
Capacity: | 115 L | Rated Voltage: | 220V±10%50Hz |
Working Environment: | 5℃~40℃ | Relative Humidity: | 10%~85% |
Exhaust Temperature Preset Range: | 73℃—104℃ | Pressure Gauge Display Range: | 0~0.6Mpa |
High Light: | 115L Automatic Autoclave Sterilizer,115L vertical autoclave sterilizer,CE Automatic Autoclave Sterilizer |
Product Description
Automatic Fault Detection System Overvoltage Test Automatic Autoclave Sterilizer
Automatic Autoclave Sterilizer Sterilization mode :
◆ Solid mode: heating → sterilization → exhaust, air cooling
◆ Liquid mode: heating → sterilization → pre-cooling → exhaust
◆ Liquid belt insulation mode: heating → sterilization → pre-cooling → exhaust → heat preservation ◆Waste mode: heating → sterilization → exhaust, air cooling
◆ Agar mode: heating → melting → heat preservation
model | CT115 Standard sterilizer | ||
Sterilization working temperature | 105℃~138℃ | ||
Sterilization time preset range | 1 minute~6000 minutes | ||
Preset range of melting temperature | 60℃~100℃ | ||
Preset range of melting time | 1 minute~6000 minutes | ||
Preset range of holding temperature | 45℃~60℃ | ||
Preset range of holding time | 1 minute~9999 minutes | ||
Cooling lock opening temperature range | solid,agar and waste models 40℃~99℃,Liquid mode 40℃~80℃ | ||
Exhaust temperature preset range | 73℃—104℃ | ||
Preset range of door opening temperature | solid,agar and waste models 40℃~99℃,Liquid mode 40℃~80℃ | ||
Clock function | Operation time can be set (year,Month,Day,Time,Minute) | ||
Timer preset range | Query current time (year,Month,Day,Time,Minute) | ||
Total number of sterilization and failure time and code | |||
Pressure gauge display range | 0~0.6Mpa |
Automatic Autoclave Sterilizer Performance characteristics :
◆ The display screen and pressure gauge of the CT-series autoclave are on the same plane, making the operation and reading of the autoclave equally convenient. The keyboard function of the autoclave has clear instructions, the autoclave can retain the preset mode, and the autoclave can automatically complete all the tasks of the autoclave with one button start
◆ The quick-locking lever can easily lock the sterilization hatch of the autoclave, and the automatic hinge of the autoclave makes it easy to pick up and put down the hatch.
◆ The double inner lock device ensures the lock of the hatch during the operation of the autoclave and keeps the temperature within a safe range.
◆ The status image display of the autoclave, the autoclave can clearly display the current working status.
◆ Large-diameter sterilization chamber: The 40cm large-diameter sterilization chamber provides a large space to meet various sterilization needs.
◆ Intelligent control system: The microcomputer chip intelligent control system monitors the temperature and pressure in the sterilization chamber in real time. The cover of the sterilization chamber can only be opened at a safe temperature and pressure to ensure the safety of users. At the same time, the automatic control of the sterilization process is realized, and maintenance, query, verification, recording, and future expansion and upgrading can be carried out conveniently.
◆ Six preset programs: preset six fixed programs for liquid sterilization and heat preservation, solid sterilization and drying, agar melting heat preservation and waste sterilization, etc
◆ Pressure performance: The cavity design pressure reaches 0.4Mpa, and each instrument passes the test water pressure of up to 0.5Mpa. The leading pressure guarantee ensures the safe load of the instrument.
◆ One-key query function: you can query the current time, the total number of sterilizations, the time of failure and the code.
◆ Door opening temperature: Each program can set the door opening temperature of the cooling lock according to the thermal inertia of the sterilized material to prevent users from opening the lid of the sterilized material (especially liquid sterilized material) and causing burns when it is still in an unsafe state.