Electric Cell Culture BSC Biosafety Cabinet Class 2 Type A2
Product Details:
Place of Origin: | CHINA |
Brand Name: | HAIYING |
Certification: | CE |
Model Number: | BSC-1000A2 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiable |
Packaging Details: | Wooden case |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Detail Information |
|||
Features: | Electric Front Window | Type: | Blood Testing Equipments |
---|---|---|---|
Overall Size: | 1200×800×2120mm | Purification Area Size: | 1000×700×600mm |
Product Name: | Biosafety Cabinet | Model: | BSC-1000A2 |
Downflow Velocity: | 0.31±0.025m/s | Inflow Velocity: | 0.48±0.025m/s |
High Light: | Class 2 BSC Biosafety Cabinet,Electric biosafety cabinet class 2 type a2,A2 BSC Biosafety Cabinet |
Product Description
Model | BSC-1000A2 |
Clean Grade | HEPA:ISO 5 calss ( Class100 ) |
ULPA:ISO 4 Class ( Class10 ) | |
HEPA Filter | HEPA:≥99.995% , @0.3μm |
ULPA:≥99.999% , @0.12μm | |
Air tightness | 99.99≤E≤99.999 |
Overall Dimensions | 1200×800×2120mm |
Working Space | 1000×700×600mm |
Downflow Velocity | 0.35m/s |
Forward intake wind speed | 0.25m/s±0.025m/s |
Classification of BSC Biosafety Cabinet:
According to the NSF49 standard, the medium of biosafety level 1 (P1) refers to ordinary harmless bacteria, viruses and other microorganisms; the medium of biosafety level 2 (P2) refers to general pathogenic bacteria, viruses and other microorganisms; biosafety The medium of level 3 (P3) refers to microorganisms such as potent/fatal bacteria and viruses, but can be cured after infection; the medium of biosafety level 4 (P4) refers to microorganisms such as potent/fatal bacteria, viruses, etc., and it is not easy to cure after infection . This standard divides biological safety cabinets into levels I, II, and III, which can be applied to the operation of media with different levels of biological safety.
Principles for choosing BSC Biosafety Cabinet in biosafety laboratories:
When the laboratory level is level 1, there is generally no need to use a biological safety cabinet or a level I biological safety cabinet. When the laboratory level is level two, when microbial aerosols or spills may occur, a level I biological safety cabinet can be used; when handling infectious materials, a level II biological safety cabinet with partial or full ventilation should be used ; If it involves handling chemical carcinogens, radioactive substances and volatile solvents, only Class II-B full exhaust (B2 type) biological safety cabinets can be used. When the laboratory level is level three, a level II or level III biological safety cabinet should be used; all operations involving infectious materials should use a fully exhausted type II-B level (B2 type) or level III biological safety cabinet. When the laboratory level is level four, a level III full exhaust biological safety cabinet should be used. When personnel wear positive pressure protective clothing, a Class II-B biological safety cabinet can be used.