High Security Low Speed Centrifuge For Biochemistry Medicine Pharmacy
Product Details:
Place of Origin: | China |
Brand Name: | HAIYING |
Model Number: | TD4 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Negotiable |
Packaging Details: | Carton |
Payment Terms: | L/C, D/A, D/P, T/T |
Detail Information |
|||
Product Name: | Low Speed Centrifuge | Maximum Speed(r/min): | 4000 R/min |
---|---|---|---|
Noise: | ≤60dB | Maximum Capacity: | 8×20 Ml |
Weight: | 18000 G | Dimensions (length×width×height): | 38×26×31 Cm |
High Light: | High Security Low Speed Centrifuge,Biochemistry Low Speed Centrifuge,4000r/min variable speed centrifuge |
Product Description
High Security Cost-Effective For Biochemistry Medicine Pharmacy Centrifuge
TD4 Low Speed Centrifuge Common failure analysis:
1. After the power is turned on, the control panel displays normal, and the cooling fan works normally. When the start button is pressed, the intermediate relay works and the centrifuge does not work. According to the analysis of the fault phenomenon, the power supply part and the control part should be normal, and the fault should be at the line from the control board to the motor, the carbon brush and the motor. Turn on the centrifuge, use a multimeter to measure the continuity of the line from the control board to the carbon brush, and then measure that the carbon brush does not conduct when it reaches the motor rotor. Carefully observe the poor contact between the carbon brush and the motor rotor. Remove the carbon brush and find that it has been used for too long. Caused by too short. Replace with a new carbon brush, troubleshooting. This kind of failure is a common failure of the centrifuge, and the carbon brushes should be replaced regularly to avoid the above failures.
2. After the power is turned on, the control panel displays normal, and the cooling fan works normally. When the start button is pressed, the intermediate relay does not work and the centrifuge does not work. According to the analysis of the fault phenomenon, the power supply part should be normal, and the fault should be in the control board and the circuit to the motor, carbon brush and motor. Turn on the centrifuge, use a multimeter to measure the continuity of the circuit from the control board to the carbon brush, and then measure the continuity of the carbon brush to the motor rotor, and the measured motor coil is normal. After starting up, use a multimeter to measure the non-voltage output of the wire from the control board to the motor. It can be judged that the fault should be on the control board. The intermediate relay does not work. The fault should be on the control circuit that controls the intermediate relay. Eliminate one by one, and find C9013 on the control board. The triode breakdown, the new C9013 triode is worse, troubleshooting.
Host technical parameters | |
Timing range | 1-99h59min/continuous/short time centrifugation |
noise | ≤60dB |
power | 120W |
power supply | AC220V 50Hz |
Weight (with rotor) | 18 Kg |
Dimensions (length×width×height) | 380×260×310 mm |
Shandong Haiying Wuzhou Instrument Co., Ltd.
Strong qualifications, brand certification
◆ Professional power
Sets of medical equipment, pharmaceutical equipment of scientific research, production and sales, medical service, trade logistics in various fields of domestic leading health industry group.
◆ Professional power
The infection control equipment production of varieties and ranked among the top of the world; Radiation therapy equipment r &d and production in domestic large scale, complete varieties, domestic market share is high, the technical level of lead.
◆ Quality management
With medical devices and equipment, pharmaceutical equipment, medical services,- medical commerce four business sectors.Advanced technology, strong innovation ability, selections of the management system, and perfect service.