Interlock Class II A2 Biosafety Cabinets Stainless Steel
Product Details:
Place of Origin: | CHINA |
Brand Name: | HAIYING |
Certification: | CE |
Model Number: | BSC-1300A2 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiable |
Packaging Details: | Wooden case |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Detail Information |
|||
Model: | Class II A2 Biosafety Cabinets | Type: | Blood Testing Equipments |
---|---|---|---|
Model: | BSC-1300A2 | Overall Size: | 1500×800×2120mm |
Purification Area Size: | 1300×700×600mm | Product Name: | Biosafety Cabinet |
Inside Of The Door: | 0.38±0.025m/s | Front Inflow Air: | 0.48±0.025m/s |
High Light: | Blood Class II A2 Biosafety Cabinets,0.4mps laboratory biosafety cabinet,0.4mps Class II A2 Biosafety Cabinets |
Product Description
Interlock Function Double Person Stainless Steel Class II Type A2 Biosafety Cabinet
Class II Type A2 Biosafety Cabinet Feature:
* LCD display
The large digital display makes it easy to monitor all safety parameters, and the ergonomically sized control panel improves the user interface.
* Working area
The working area is made of 304 stainless steel, surrounded by negative pressure.
* remote control
You can use it to achieve all functions, making the operation easier.
* ultra violet light
The most effective purification
* Front window
Two layers of laminated tempered glass,> 5mm, UV resistant
* Foot switch
During the experiment, adjust the height of the front window with your feet to avoid turbulence caused by arm movement.
* Waterproof socket
The waterproof socket is located on the side wall, which provides the greatest convenience for using small equipment inside the cabinet.
Model | BSC-1300A2 |
Clean Grade | HEPA:ISO 5 calss ( Class100 ) |
ULPA:ISO 4 Class ( Class10 ) | |
HEPA Filter | HEPA:≥99.995% , @0.3μm |
ULPA:≥99.999% , @0.12μm | |
Air tightness | 99.99≤E≤99.999 |
Overall Dimensions | 1500×800×2120 mm |
Working Space | 1300×700×600 mm |
Inside of the door | 0.38±0.025m/s |
Front inflow air | 0.48±0.025m/s |
Class II Type A2 Biosafety Cabinet Precautions:
1. In order to avoid cross-contamination between items, the items needed during the whole work process should be lined up and placed in the safety cabinet before the work starts, so that no items need to be taken out through the air flow compartment before the work is completed or Put it in, pay special attention: no items can be placed on the front and rear return grilles to prevent the return grills from being blocked and affecting the air circulation.
2. Before starting work and after finishing work, it is necessary to maintain the air circulation for a period of time to complete the self-cleaning process of the safety cabinet. The cabinet should be cleaned and disinfected after each test.
3. During the operation, try to reduce the number of arms in and out as much as possible, and the arms should be slow when entering and exiting the safety cabinet to avoid affecting the normal airflow balance.
4. The movement of items in the cabinet should follow the principle of moving from low pollution to high pollution, and the experiment operation in the cabinet should be carried out in the direction from the clean area to the contaminated area. Before operation, a towel soaked with disinfectant can be used as a bottom to absorb any droplets that may spill.
5. Try to avoid placing centrifuges, oscillators and other instruments in a safety cabinet to prevent the particulate matter on the filter membrane from shaking off when the instrument shakes, resulting in a decrease in the cleanliness of the cabinet; at the same time, the airflow of the heat dissipation vents of these instruments may affect the cabinet. The airflow balance.
6. Do not use open flames in the safety cabinet to prevent the high temperature and fine particles generated during the combustion process from being brought into the filter membrane and damage the filter membrane.