LCD Automatic Timing Desktop Autoclave Sterilizer 23 L
Product Details:
Place of Origin: | China |
Brand Name: | HAIYING |
Certification: | CE certificate |
Model Number: | BTS23-A |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Price: | Negotiable |
Packaging Details: | Wooden case |
Delivery Time: | 5-8 work days |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 10000 Set/Sets per day |
Detail Information |
|||
Features: | Automatic Timing | Tybe: | BTS23-A |
---|---|---|---|
Chamber Volume: | 23 L | Chamber Dimension: | 250mm * 450mm |
Operating Environment Temperature: | 5 ºC ~ 40 ºC | Nominal Power: | 2.0 Kw |
Net Weight: | 52 Kg | Advantage: | Anti-Scald Protective Cover |
High Light: | 52 kg Desktop Autoclave Sterilizer,23 L portable pressure steam sterilizer,23 L Desktop Autoclave Sterilizer |
Product Description
LCD Automatic Timing Anti-Scald Protective Cover Desktop Autoclave Sterilizer
Product Usage of Desktop Autoclave Sterilizer:
The sterilizer is a fast sterilization desktop equipment with safe and reliable automatic control program. Using the European CLASS N standard, with beautiful appearance, it is the most sophisticated and economical medical equipment to sterilize solids.
The Sterilizer is suitable for health care center, pharmaceutical companies and research institutes etc. Providing sterilization for the items that are resistant to saturated steam, such as surgical dental ophthalmic instruments, glassware, chemicals, culture media, fabric accessories and food.
Model | BTS23-A |
Nominal voltage | AC100/220v , 50HZ /60HZ |
Nominal power | 2000W |
Sterilization temperature(user-defination) | 121 ºC / 134 ºC (Custom105 ºC - 134ºC) |
Operating environment temperature | 5 ºC ~ 40 ºC |
Desktop Autoclave Sterilizer Operating specifications---Preparation before use:
◆ Water tank, add pure water or as required in accordance with the requirements after connecting water, connection equipment power supply.
◆ Sterilizer, turn on the power supply, the power switch in the on state, to be prepared for the program is running;
◆ According to the specified requirements or load type, select the BD program or preheat (for example, if is the class B load with a cavity, generally need to first run BD application, if all are exposed solid equipment can run the preheating process) onto a BD indicate the operator's name or code, date, such as tag, run out into the south in BD experimental procedures, monitoring equipment without leakage, the equipment is normal.
◆ stay sterilization package, strapping not too tight, the built-in chemical indicator CARDS, chemical indicator tape is stuck outside.
Desktop Autoclave Sterilizer Operating specifications---Sterilization operations:
◆ According to the specified requirements of qualified experiment in BD or after preheating, will stay sterilization items in the sterilization room, around the bag and bag should leave gaps between don't stick on the wall and door plank;
◆ Sterilizer, close the door, according to the sterilization items selected sterilization procedures, check whether the sterilization parameters correctly, start the program:
◆ Sterilization process, the operator shall not be far away from the equipment, should closely observe the equipment running status, if there are any abnormalities, and processed in a timely manner, to prevent accidents
◆ Completes the sterilization effect of monitoring, record purpose, easy to track survey;
◆ End of the sterilization, after waiting for indoor pressure back to zero, can open the door to take out the items
◆ After sterilization items from the sterilizer, carefully placed up, prevent secondary pollution.
Desktop Autoclave Sterilizer Operation after use:
◆ open cupboard door, will the power switch in the off state, to cut off the equipment power supply:
◆ Water quality is poor or run after five fire bacteria process must change water:
◆ Evaporator, monthly cleaning (cleaning method in accordance with the manual)
◆ At the end of the daily work, sterilizer should be kept clean inside and outside, you should use a clean cloth and water chamber dirt" clean, according to the instruction weekly maintenance, monthly maintenance.