LCD Instrument Class II A2 Biosafety Cabinets
Product Details:
Place of Origin: | CHINA |
Brand Name: | HAIYING |
Certification: | CE |
Model Number: | BHC-1000A2 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiable |
Packaging Details: | Wooden case |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Detail Information |
|||
Type: | Blood Testing Equipments | Model: | BHC-1000A2 |
---|---|---|---|
Overall Size: | 1200×750×1950mm | Purification Area Size: | 1000×650×580mm |
Product Name: | Biosafety Cabinet | Inside Of The Door: | 0.38±0.025m/s |
Front Inflow Air: | 0.48±0.025m/s | Illumination: | ≥700LX |
High Light: | 700LX Class II A2 Biosafety Cabinets,700LX biosafety cabinet class 2 a2,HEPA Filter Class II A2 Biosafety Cabinets |
Product Description
For chemical laboratories LCD instrument Class II A2 Biosafety Cabinets
Class II A2 Biosafety Cabinets Features:
◆ Triple protection: operator, sample and environment.
◆ Airflow system: 70% air recirculation, 30% exhaust
◆ The A2 cabinet is suitable for microbiological research in the absence of volatile or toxic chemicals and radionuclides.
◆ Biosafety cabinet CE certified biosafety cabinet.
◆ The control board is microprocessor controlled. Customers can get supervision of all cabinet functions.
◆ The large LCD display shows all information.
◆ The workbench is integrated with stainless steel and can be moved completely to keep the lower surface clean and sterile
◆ Electric front window.
◆ Automatic wind speed, with filter block.
◆ The side and back wall are made of a single piece of stainless steel with a 45° angle
◆ Lean forward 10°, which can provide the operator with a sense of comfort when working for a long time, reduce glare and extend into the work area to the greatest extent.
◆ Interlock function: UV lamp and front window; UV lamp and blower, fluorescent lamp; blower and front window.
◆ The work area is equipped with a socket
◆ Split structure, cabinet and bracket can be separated.
◆ The negative pressure channel design on all sides avoids the diffusion of harmful gases and aerosols, making it safer and more reliable.
◆ Adopt German imported fan, with low noise and large air volume.
Model | BHC-1000A2 |
Clean Grade | HEPA:ISO 5 calss ( Class100 ) |
ULPA:ISO 4 Class ( Class10 ) | |
HEPA Filter | HEPA:≥99.995% , @0.3μm |
ULPA:≥99.999% , @0.12μm | |
Air tightness | 99.99≤E≤99.999 |
Overall Dimensions | 1200×750×1950 mm |
Working Space | 1000×650×580 mm |
Inside of the door | 0.38±0.025m/s |
Front inflow air | 0.48±0.025m/s |
Principles for choosing Class II A2 Biosafety Cabinets in biosafety laboratories:
When the laboratory level is level 1, there is generally no need to use a biological safety cabinet or a level I biological safety cabinet. When the laboratory level is level two, when microbial aerosols or spills may occur, a level I biological safety cabinet can be used; when handling infectious materials, a level II biological safety cabinet with partial or full ventilation should be used ; If it involves handling chemical carcinogens, radioactive substances and volatile solvents, only Class II-B full exhaust (B2 type) biological safety cabinets can be used. When the laboratory level is level three, a level II or level III biological safety cabinet should be used; all operations involving infectious materials should use a fully exhausted type II-B level (B2 type) or level III biological safety cabinet. When the laboratory level is level four, a level III full exhaust biological safety cabinet should be used. When personnel wear positive pressure protective clothing, a Class II-B biological safety cabinet can be used.