NSF/ANSI49 Standard 1300B2II BSC Biosafety Cabinet Noise 65db
Product Details:
Place of Origin: | CHINA |
Brand Name: | HAIYING |
Model Number: | BSC-1300B2II |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
---|---|
Price: | USD 9200 set |
Packaging Details: | Wooden case |
Detail Information |
|||
Type: | BSC Biosafety Cabinet | Product Name: | Biosafety Cabinet |
---|---|---|---|
Model: | BSC-1300B2II | Noise: | ≤65db |
Standard: | NSF/ANSI49 Standard | Downflow Velocity: | 0.31±0.025m/s |
Inflow Velocity: | 0.48±0.025m/s | Power Supply: | 220V 50Hz |
High Light: | 1300B2II BSC Biosafety Cabinet,ANSI49 BSC Biosafety Cabinet,NSF BSC Biosafety Cabinet |
Product Description
NSF/ANSI49 Standard 1300B2II BSC Biosafety Cabinet Noise 65db
BSC Biosafety Cabinet Features:
1. The product design meets the requirements of the YY0569 standard of China CFDA and the second-level biological safety cabinet in the American NSF/ANSI49 standard.
◆ The front window glass door is designed with a 10° physiological oblique angle, and the viewing angle is larger and ergonomic, and the operation is more comfortable. The double-layer cabinet surrounded by negative pressure prevents leakage and pollution.
2. Intelligent man-machine interface
◆ Touch 7-inch high-definition LED display. Intelligent management equipment.
◆ Air volume automatic compensation technology. The fan is automatically adjusted when the wind speed is abnormal.
3. Mature processing technology
◆ The front window glass is made of explosion-proof toughened glass that has clear optical perspective and does not negatively affect it during cleaning and disinfection.
4. Strict factory inspection
◆ Leakage detection of the cabinet body, there is no leakage after the safety cabinet is pressurized to 500Pa.
BSC Biosafety Cabinet Parameters:
Model | BSC-1300B2II |
Clean Grade | HEPA:ISO 5 calss ( Class100 ) |
ULPA:ISO 4 Class ( Class10 ) | |
HEPA Filter | HEPA:≥99.995% , @0.3μm |
ULPA:≥99.999% , @0.12μm | |
Overall Dimensions | 1480 x 790 x 2210mm |
Working Space | 1300 x 672 x 630mm |
Downflow Velocity | 0.35m/s |
Inflow Velocity | 0.53m/s |
Noise Level | ≤63dB |
Illumination | ≥700lx |
Light | 30Wx2 |
Ultraviolet Light | 30Wx1 |
Max. Power(with Plug) | 1500W |
Power Supply | 220V 50Hz |
Principles for BSC Biosafety Cabinet
When the laboratory level is level 1, there is generally no need to use a biological safety cabinet or a level I biological safety cabinet. When the laboratory level is level two, when microbial aerosols or spills may occur, a level I biological safety cabinet can be used; when handling infectious materials, a level II biological safety cabinet with partial or full ventilation should be used ; If it involves handling chemical carcinogens, radioactive substances and volatile solvents, only Class II-B full exhaust (B2 type) biological safety cabinets can be used. When the laboratory level is level three, a level II or level III biological safety cabinet should be used; all operations involving infectious materials should use a fully exhausted type II-B level (B2 type) or level III biological safety cabinet. When the laboratory level is level four, a level III full exhaust biological safety cabinet should be used. When personnel wear positive pressure protective clothing, a Class II-B biological safety cabinet can be used.