Vertical Air Supply Class II A2 Biosafety Cabinets LCD Panel
Product Details:
Place of Origin: | CHINA |
Brand Name: | HAIYING |
Certification: | CE |
Model Number: | BHC-1600A2 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 set |
---|---|
Price: | Negotiable |
Packaging Details: | Wooden case |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Detail Information |
|||
Type: | Blood Testing Equipments | Model: | BHC-1600A2 |
---|---|---|---|
Overall Size: | 1500×750×1950mm | Purification Area Size: | 1300×650×580mm |
Product Name: | Biosafety Cabinet | Inside Of The Door: | 0.38±0.025m/s |
Front Inflow Air: | 0.48±0.025m/s | Mode: | Class II A2 Biosafety Cabinets |
High Light: | LCD panel Class II A2 Biosafety Cabinets,0.505mps benchtop biosafety cabinet,oem Class II A2 Biosafety Cabinets |
Product Description
For chemical laboratories Vertical air supply Class II A2 Biosafety Cabinets
Class II A2 Biosafety Cabinets Product introduction:
It is widely used in biosafety protection and isolation equipment in microbiology, biomedicine, biological laboratories and other laboratories. It adopts advanced air purification technology and negative pressure cabinet design to realize the protection of the environment, personnel and samples and prevent harmfulness. The diffusion of suspended particles and aerosols.
Class II A2 Biosafety Cabinets Features:
◆ Air curtain isolation design can prevent internal and external cross contamination. (Negative pressure type)
◆ Move the glass door up and down and display the height limit alarm prompt for the operator to use it correctly.
◆ Using HEPA non-separator high efficiency filter, the filtration efficiency reaches 99.999%.
◆ Adopt LCD panel control, fan failure alarm prompt, prompt prompt of start-up time and continuous running time, prompt display of filter life.
◆ With timing sterilization and sterilization timing functions. (With UV protection device, the UV lamp will automatically turn off after opening the operating door 2 cm)
◆ The inclined design of the cabinet accords with ergonomics, which increases the operating comfort.
◆ The four sides of the operating area are made of 304 high-quality stainless steel. The back and sides are integrally formed on three sides, no welding and no leakage. The exhaust outlet direction is the ejector.
Model | BHC-1600A2 |
Clean Grade | HEPA:ISO 5 calss ( Class100 ) |
ULPA:ISO 4 Class ( Class10 ) | |
HEPA Filter | HEPA:≥99.995% , @0.3μm |
ULPA:≥99.999% , @0.12μm | |
Air tightness | 99.99≤E≤99.999 |
Overall Dimensions | 1500×750×1950 mm |
Working Space | 1300×650×580 mm |
Inside of the door | 0.38±0.025m/s |
Front inflow air | 0.48±0.025m/s |
Installation of Class II A2 Biosafety Cabinets:
1. The biological safety cabinet shall not be placed on its side, impacted, or collided during transportation, and shall not be directly attacked by rain, snow, or sun exposure.
2. The working environment of the biological safety cabinet is 10~30℃ and the relative humidity is <75%.
3. The equipment should be installed on a horizontal surface that cannot be moved.
4. The equipment must be installed close to a fixed power socket. When the external exhaust system is not connected, the top of the device must be at least 200mm away from the obstacle at the top of the room, and the distance between the back and the wall must be at least 300mm to facilitate the smooth flow of external exhaust. Maintenance of safety cabinets.
5. In order to prevent airflow interference, it is required not to install the equipment in the passage of people, and not to make the operating port of the sliding front window of the biological safety cabinet face the door and window of the laboratory or be too close to the door and window. Places that may disturb the airflow.
6. When used in high altitude areas, the wind speed must be recalibrated after installation.