HR26M Large Capacity Refrigerated Centrifuge 25000 Rpm
Product Details:
Place of Origin: | CHINA |
Brand Name: | HAIYING |
Certification: | CE |
Model Number: | HR26M |
Payment & Shipping Terms:
Minimum Order Quantity: | 1 Set |
---|---|
Price: | discuss personally |
Packaging Details: | wooden case |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Detail Information |
|||
Features: | Wide Temperature Control | Type: | HR26M |
---|---|---|---|
Max RCF: | 58696×g | Max Speed: | 25000r/min |
Max Capacity: | 4×1000mL | Timer Range: | 1min-99h59min,with Continuous Run Function |
Power Supply: | AV220V 50Hz | Temp Control Range: | -20℃~+40℃ |
High Light: | HR26M Large Capacity Refrigerated Centrifuge,HR26M high volume centrifuge,25000rpm Large Capacity Refrigerated Centrifuge |
Product Description
Large Capacity Refrigerated Centrifuge Features:
1. LCD display, microprocessor control, large capacity refrigerated centrifuge can display the set parameters and actual parameters at the same time.
2. AV motor: high torque and variable frequency, free from carbon dust pollution.
3. Imported drive system and automatic control system ensure stable and reliable operation.
4. Safety: overheating and overspeed protection, electronic locking, unbalance detection.
5. Multiple programs can be set, and parameters can be modified during operation.
6. Multi-level acceleration and deceleration control.
Max RCF
|
58696×g
|
Max Speed
|
25000r/min
|
Max Capacity
|
4×1000mL
|
Timer Range
|
1min-99h59min, with continuous run function
|
Temp control range
|
-20℃~+40℃
|
Noise level
|
≤65dB(A)
|
Power supply
|
AC220V 50Hz
|
Large Capacity Refrigerated Centrifuge instructions:
1. the host should be placed without heat source, the source, no electromagnetic interference, "ventilation, no direct sunlight" flat solid work surface or ground;
2. connect the power supply, pay attention to the power supply voltage and capacity;
3. open the host cover, tighten the rotor to the drive shaft, completes the balance samples (sample equivalent axisymmetric placed), cover door cover;Number
4. select the correct rotor, set speed (RCF), speed, temperature, the separation of time;
5. press the start key to start the;
6. arrived at the set time, the instrument automatically stop; The door cover, take out separate good sample, centrifugal is complete;
7. centrifugal, after the completion of the chamber and the engine clean, and to turn it off.
Large Capacity Refrigerated Centrifuge Use Notice:
1. pay attention to use correct rotor, no speeding operation.
2. completes the sample amount of axisymmetric placed in the rotor, run rotor balanceOperating this product by the laboratory professionals, not used to treat, scope of application, taboos, adverse reactions, no risk to the public.
Large Capacity Refrigerated Centrifuge Note:
1. not in damp, high temperature and dust use centrifuge;
2. please make sure that before starting the equipment level, to receive strength evenly in the four corners, balancing centrifugal samples is good, be sure to with an even symmetry in the centrifuge tube. If big shake appeared in the process of operation, please stop the machine immediately to check;
3. In order to ensure safety, be sure to check before starting the rotor, it is forbidden to overspeed centrifugal;
4. In the process of operation, it is forbidden to move the centrifuge, prohibit open;
5. After the separation, please timely lumen from the centrifuge will be clean and prevent rust. If long time no centrifuge, need to remove the rotor, wipe clean place. Set aside. Time is too long can lead to the rotor and the motor shaft rust, remove difficulties;
6. Often should rotor of centrifuge, the centrifugal tube, adapter, such as inspection, have crack, aging phenomenon is found, please change in time.