Type: Blood Testing Equipments Model: BSC-1600B2
Mode: Class II B2 Biosafety Cabinet Overall Size: 1800×800×2120MM
Purification Area Size: 1600×700×600MM Product Name: Biosafety Cabinet
Inside Of The Door: 0.38±0.025m/s Front Inflow Air: 0.48±0.025m/s
Highlight:

CE Class II B2 Biosafety Cabinet

,

HAIYING biosafety cabinet class 2 b2

,

BSC 1600B2 Class II B2 Biosafety Cabinet

Product Description

Biological experiments 100 level protection Class II B2 Biosafety Cabinet

Biological experiments 100 level protection Class II B2 Biosafety Cabinet is a box-type air purification negative pressure safety device that can prevent aerosols containing dangerous or unknown biological particles from escaping during the process of experimental operation. It is widely used in scientific research, teaching, clinical testing and production in the fields of microbiology, biomedicine, genetic engineering, and biological products. It is the most basic safety protection equipment in the first-level protective barrier of laboratory biosafety.

Class II B2 Biosafety Cabinet Working Principle:
The working principle of Biological experiments 100 level protection Class II B2 Biosafety Cabinet is mainly to suck the air inside the cabinet to maintain a negative pressure in the cabinet, and protect the staff through vertical airflow; the outside air is passed through a high-efficiency air filter (high- Efficiency particulate air filter, HEPA filter) enter the safety cabinet after filtering to avoid contamination of the processed samples; the air in the cabinet also needs to be filtered by the HEPA filter before being discharged into the atmosphere to protect the environment.

 

Model BSC-1600B2
Clean Grade HEPA:ISO 5 calss ( Class100 )
ULPA:ISO 4 Class ( Class10 )
HEPA Filter HEPA:≥99.995% , @0.3μm
ULPA:≥99.999% , @0.12μm
Air tightness 99.99≤E≤99.999
Overall Dimensions 1800×800×2120
MM
Working Space 1600×700×600
MM
Inside of the door 0.38±0.025m/s
Front inflow air 0.48±0.025m/s
 

 

Biological experiments 100 level protection Class II B2 Biosafety Cabinet structure
Biological experiments 100 level protection Class II B2 Biosafety Cabinet generally consists of a cabinet and a bracket. The cabinet part mainly includes the following structures:
1.  Air Filtration System
The air filtration system is the most important system to ensure the performance of the Biological experiments 100 level protection Class II B2 Biosafety Cabinet. It consists of a driving fan, an air duct, a circulating air filter and an external exhaust air filter. Its main function is to continuously bring clean air into the working room, so that the flow rate of the sinking airflow (vertical airflow) in the working area is not less than 0.3m/s, and ensuring the cleanliness of the working area reaches Class 100. At the same time, the external exhaust flow is also purified to prevent environmental pollution.
The core component of the system is a HEPA filter, which uses a special fire-resistant material as the frame. The frame is divided into grids with corrugated aluminum sheets, filled with emulsified glass fiber sub-fine particles, and its filtration efficiency can reach 99.99% to 100%. The pre-filter cover or pre-filter at the air inlet makes the air pre-filtered and purified before entering the HEPA filter, which can extend the service life of the HEPA filter.
2.  External exhaust air box system
The external exhaust air box system consists of external exhaust air box shell, fan and exhaust duct. The external exhaust fan provides exhaust power to extract the unclean air in the working room, and it is purified by the external exhaust filter to protect the samples and the experimental items in the cabinet. Due to the external exhaust, the working room is under negative pressure to prevent The air in the work area escapes to protect the operator.
3.  Sliding front window drive system
The sliding front window drive system is composed of the front glass door, door motor, traction mechanism, drive shaft and limit switch, etc. The main function is to drive or traction each door shaft so that the front glass door is in the normal position during the operation of the equipment.
4.  The illuminating light source and ultraviolet light source are located inside the glass door to ensure a certain brightness in the working room and to disinfect the work surface and air in the working room.